Charlene's Scholastic Emporium.
Your Actual and Virtual Exam Tests Excellent Tutor.
- 10060
- 0
- 759
Community
- Followers
- Following
14 Reviews received
12 items
CT REGISTRY EXAM QUESTIONS AND ANSWERS 100% PASS
CT REGISTRY EXAM QUESTIONS AND 
ANSWERS 100% PASS 
how do you reduce beam hardening - Correct Answer ️️ -1. Increase dose 
2. Reduce collimation--Reduce slice thickness 
3. Increase window width 
At what level does the abdominal aortal bifurcate? - Correct Answer ️️ -L4 
What is the typical scan delay after injection of contrast media for studies of the liver? - 
Correct Answer ️️ -30-45 seconds 
What window settings provide the best tissue differentiation within the liver? - Correct...
- Exam (elaborations)
- • 89 pages •
CT REGISTRY EXAM QUESTIONS AND 
ANSWERS 100% PASS 
how do you reduce beam hardening - Correct Answer ️️ -1. Increase dose 
2. Reduce collimation--Reduce slice thickness 
3. Increase window width 
At what level does the abdominal aortal bifurcate? - Correct Answer ️️ -L4 
What is the typical scan delay after injection of contrast media for studies of the liver? - 
Correct Answer ️️ -30-45 seconds 
What window settings provide the best tissue differentiation within the liver? - Correct...
CT registry- image production Exam Questions and Answers 100% Pass
CT registry- image production Exam 
Questions and Answers 100% Pass 
Fundamental principle of ct may be summarized as - Correct Answer ️️ -An image of 
an object may be reconstructed on the basis of the attenuation that occurs as x 
radiation is transmitted through it 
Detectors measure - Correct Answer ️️ -The radiation that is transmitted through the 
pt. An image is reconstructed in the basis of the magnitude of X-ray attenuation that 
occurs at spatially distributed points within the...
- Package deal
- Exam (elaborations)
- • 48 pages •
CT registry- image production Exam 
Questions and Answers 100% Pass 
Fundamental principle of ct may be summarized as - Correct Answer ️️ -An image of 
an object may be reconstructed on the basis of the attenuation that occurs as x 
radiation is transmitted through it 
Detectors measure - Correct Answer ️️ -The radiation that is transmitted through the 
pt. An image is reconstructed in the basis of the magnitude of X-ray attenuation that 
occurs at spatially distributed points within the...
Mosby CT Registry Review 2024 Questions and Answers 100% Pass
Mosby CT Registry Review 2024 
Questions and Answers 100% Pass 
What is the smallest component of a digital image - Correct Answer ️️ -pixel 
How many CT numbers are assigned to each pixel in the image matrix? - Correct 
Answer ️️ -One 
In a CT image, the CT number - Correct Answer ️️ -Of a material is dependent on its 
linear attenuation coefficient 
Each two-dimensional square of data that make up the CT image is called a - Correct 
Answer ️️ -pixel 
What is an element of the d...
- Package deal
- Exam (elaborations)
- • 76 pages •
Mosby CT Registry Review 2024 
Questions and Answers 100% Pass 
What is the smallest component of a digital image - Correct Answer ️️ -pixel 
How many CT numbers are assigned to each pixel in the image matrix? - Correct 
Answer ️️ -One 
In a CT image, the CT number - Correct Answer ️️ -Of a material is dependent on its 
linear attenuation coefficient 
Each two-dimensional square of data that make up the CT image is called a - Correct 
Answer ️️ -pixel 
What is an element of the d...
CT Registry Review (MIC) Questions and Answers 100% Pass
CT Registry Review (MIC) Questions and 
Answers 100% Pass 
In order for an x-ray photon to be measured it must: 
1. enter the detector chamber 
2. be absorbed by the detector material 
3. be converted to a measurable event - Correct Answer ️️ -1,2,3 
Which system component converts the projection attenuation data into the proper digital 
form for the array processor? - Correct Answer ️️ -analog-to-digital converter 
Which of the following is NOT a function of a PACS system? 
a. reconstru...
- Package deal
- Exam (elaborations)
- • 62 pages •
CT Registry Review (MIC) Questions and 
Answers 100% Pass 
In order for an x-ray photon to be measured it must: 
1. enter the detector chamber 
2. be absorbed by the detector material 
3. be converted to a measurable event - Correct Answer ️️ -1,2,3 
Which system component converts the projection attenuation data into the proper digital 
form for the array processor? - Correct Answer ️️ -analog-to-digital converter 
Which of the following is NOT a function of a PACS system? 
a. reconstru...
CT REGISTRY 1st exam Questions and Answers 100% Pass
- Package deal
- Exam (elaborations)
- • 46 pages •
MIC CT Registry Review - Module 2 Image Formation Questions and Answers 100% Pass
MIC CT Registry Review - Module 2 
Image Formation Questions and 
Answers 100% Pass 
Interpolation - Correct Answer ️️ -The Mathematical calculation that divides the helical 
data into raw data files into individual planar slices 
Types of methods of image reconstruction - Correct Answer ️️ --Filtered Back 
projection reconstruction 
-Iterative reconstruction 
-Cone beam reconstruction 
Filtered back projection - Correct Answer ️️ -The reconstruction method that raw data 
must go thr...
- Package deal
- Exam (elaborations)
- • 4 pages •
MIC CT Registry Review - Module 2 
Image Formation Questions and 
Answers 100% Pass 
Interpolation - Correct Answer ️️ -The Mathematical calculation that divides the helical 
data into raw data files into individual planar slices 
Types of methods of image reconstruction - Correct Answer ️️ --Filtered Back 
projection reconstruction 
-Iterative reconstruction 
-Cone beam reconstruction 
Filtered back projection - Correct Answer ️️ -The reconstruction method that raw data 
must go thr...
Arrt ct registry Questions and Answers 100% Pass
Arrt ct registry Questions and Answers 100% Pass 
1. 
The normal range of respiration of an adult is 
A. 5- 10 breaths per minute 
B. 12-20 breaths per minute 
c. 20-30 breaths per minute 
D. 35-50 breaths per minute - Correct Answer ️️ -B. 12-20 
2 
which of the following is a parenteral route of medication administration 
A. sublingual 
B. Intramuscular 
C. transdermal 
D. Oral - Correct Answer ️️ -B. Intramuscular 
3 
The preperation for a contrast- enhanced CT exam of a patient with ...
- Package deal
- Exam (elaborations)
- • 52 pages •
Arrt ct registry Questions and Answers 100% Pass 
1. 
The normal range of respiration of an adult is 
A. 5- 10 breaths per minute 
B. 12-20 breaths per minute 
c. 20-30 breaths per minute 
D. 35-50 breaths per minute - Correct Answer ️️ -B. 12-20 
2 
which of the following is a parenteral route of medication administration 
A. sublingual 
B. Intramuscular 
C. transdermal 
D. Oral - Correct Answer ️️ -B. Intramuscular 
3 
The preperation for a contrast- enhanced CT exam of a patient with ...
CT Anatomy Exam Questions and Answers 100% Correct
CT Anatomy Exam Questions and 
Answers 100% Correct 
Select side 2 to be shown first - Correct Answer ️️ -CT Anatomy of Chest 
Axial Reconstruction 
1. R. Humeral head - Correct Answer ️️ -1 
2. Oesophagus - Correct Answer ️️ -2 
3. Trachea - Correct Answer ️️ -3 
4. Left subclavian - Correct Answer ️️ -4 
5. Spine of scapula - Correct Answer ️️ -5 
6. Neck of scapula - Correct Answer ️️ -6 
1. Trachea - Correct Answer ️️ -1 
2. Rib - Correct Answer ️️ -2 
3. ...
- Package deal
- Exam (elaborations)
- • 7 pages •
CT Anatomy Exam Questions and 
Answers 100% Correct 
Select side 2 to be shown first - Correct Answer ️️ -CT Anatomy of Chest 
Axial Reconstruction 
1. R. Humeral head - Correct Answer ️️ -1 
2. Oesophagus - Correct Answer ️️ -2 
3. Trachea - Correct Answer ️️ -3 
4. Left subclavian - Correct Answer ️️ -4 
5. Spine of scapula - Correct Answer ️️ -5 
6. Neck of scapula - Correct Answer ️️ -6 
1. Trachea - Correct Answer ️️ -1 
2. Rib - Correct Answer ️️ -2 
3. ...
CT REGISTRY REVIEW 2024 QUESTIONS WITH 100% CORERCT ANSWERS
CT REGISTRY REVIEW 2024 QUESTIONS 
WITH 100% CORERCT ANSWERS 
d) digital subtraction angiography - Correct Answer ️️ -CT is commonly referred to as 
all of the following names except: A)computer tomography B)computerized axial 
tomography C) CAT-scan D)digital subtraction angiography 
c) the energy level & quantity of x-rays can be selected - Correct Answer ️️ -What 
control does the operator have over the x-rays in a CT exam: A)the temp & color of the 
x-rays can be tuned B)the phase & ...
- Package deal
- Exam (elaborations)
- • 8 pages •
CT REGISTRY REVIEW 2024 QUESTIONS 
WITH 100% CORERCT ANSWERS 
d) digital subtraction angiography - Correct Answer ️️ -CT is commonly referred to as 
all of the following names except: A)computer tomography B)computerized axial 
tomography C) CAT-scan D)digital subtraction angiography 
c) the energy level & quantity of x-rays can be selected - Correct Answer ️️ -What 
control does the operator have over the x-rays in a CT exam: A)the temp & color of the 
x-rays can be tuned B)the phase & ...
1 MIC-CT Registry Review-System Operations and Components Questions and Answers 100% Pass
1 MIC-CT Registry Review-System Operations and 
Components Questions and Answers 100% Pass 
D - Correct Answer ️️ -The slip ring on continuous rotation CT scanners: 
a. prevents the high voltage cable from winding up 
b. allows the exam to commence more rapidly 
c. eliminates the need for the reversal of gantry frame rotation 
d. all of the above 
Analog-to-digital converter - Correct Answer ️️ -Which system component converts the 
projection attenuation data into the proper digital form...
- Package deal
- Exam (elaborations)
- • 18 pages •
1 MIC-CT Registry Review-System Operations and 
Components Questions and Answers 100% Pass 
D - Correct Answer ️️ -The slip ring on continuous rotation CT scanners: 
a. prevents the high voltage cable from winding up 
b. allows the exam to commence more rapidly 
c. eliminates the need for the reversal of gantry frame rotation 
d. all of the above 
Analog-to-digital converter - Correct Answer ️️ -Which system component converts the 
projection attenuation data into the proper digital form...
INSY-3303 FINAL EXAM STUDY GUIDE WITH COMPLETE SOLUTIONS
the answers are incorrect
Product Owner/ Product Manager(POPM) SAFe Agile Exam Questions and Answers
CT DMV Knowledge Test 100% Correct Solved
Fiscal Law Final Exam QUESTIONS AND ANSWERS RATED A+ 2023|2024 UPDATE
NH Real Estate Exam Questions and Answers 100% Correct Score